MUTOH Rockhopper II Series Spécifications Page 165

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 319
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 164
Rockhopper II series printers – Maintenance Manual
166
AP-74065, Rev. 1.2, 27/09/04
5.5.7. Band Feed Correction Menu (X Length)
In this menu, you can correct the media feed distance.
To correct the media feed distance, you must first print out check patterns and measure the distance
between lines drawn in the media feed direction. Then you enter the measured value through this menu.
The system uses this entered value to determine the PF encoder resolution parameter in the firmware.
To perform an X-length Adjustment, please follow the steps mentioned below.
Step 1 : Go to Feed Adjustment.
Step 2 : Set the parameter value to 900 mm.
Step 3 : Print out the Feed Adjustment pattern.
Step 4 : Measure the printed Band Feed Correction pattern.
Step 5 : Enter the measured value as the Media Feed Distance parameter.
Vue de la page 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 318 319

Commentaires sur ces manuels

Pas de commentaire